Electric Hoist Seamless Conductor Bar with PVC Insulation

Type: Insulated
Conductor Type: Stranded
Application: Overhead
Conductor Material: Copper
Sheath Material: PVC
Insulation Material: PVC
Customization:
Gold Member Since 2024

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Product Features
  • Key Advantages
  • Application:
  • Product Parameters
  • Maintenance
  • FAQ
Overview

Basic Info.

Material Shape
Flat Wire
Range of Application
Mine
Certification
ISO9001, CCC
Bending Radius
≥750mm
Customized
Customized as Needed
Transport Package
Ply Wood Case
Specification
3P/4P/6P
Origin
China
Production Capacity
10000m/Month

Product Description

Product Description

Product Name: Seamless Safety Busbar
Product Color: Red
Conductor Material: 99.9% Industrial Pure Copper
Insulation Material: PVC, Resin
Roll Length: 1-1000 meters
Application Range: Industrial Power Transmission
 

Product Features
  • Seamless Design: Ensures consistent quality with no gaps, reducing the risk of corrosion and failure.
  • Compact Size: Ideal for space-constrained installations.
  • Minimum Bending Radius: 750mm, suitable for curved and height-adjustable designs.
  • High Conductivity: Made from 99.9% industrial pure copper for excellent conductivity.
  • Durable Insulation: PVC and resin materials provide strong impact resistance and UV resistance.
  • Easy Installation: Designed for quick and hassle-free assembly.
Electric Hoist Seamless Conductor Bar with PVC Insulation
Key Advantages

1. Seamless Design:
The seamless construction of the busbar ensures no gaps, significantly reducing the risk of corrosion and electrical failures. This design offers a longer lifespan compared to traditional busbars.

2. Flexibility and Versatility:
Our busbar can be easily bent and shaped to fit various configurations without compromising its structural integrity. This makes it an ideal choice for complex automated production environments.

3. Superior Conductivity:
Utilizing 99.9% industrial pure copper, the Seamless Safety Busbar provides exceptional electrical conductivity, ensuring efficient power transmission with minimal voltage drop.

4. Durable and Reliable:
The combination of high-quality PVC and resin materials ensures the busbar is durable, impact-resistant, and UV-resistant, suitable for demanding industrial environments.

5. Efficient and Cost-Effective:
The seamless installation design is not only simple and time-saving but also highly cost-effective. The busbar can be cut to any length as per customer requirements, providing great flexibility in various applications.

 

Technical Specifications

  • Product Name: Seamless Safety Busbar
  • Conductor Material: 99.9% Industrial Pure Copper
  • Insulation Material: PVC, Resin
  • Color: Red
  • Roll Length: 1-1000 meters
  • Minimum Bending Radius: 750mm
  • Available Specifications: 3P, 4P, 6P
Electric Hoist Seamless Conductor Bar with PVC Insulation

 

Our Seamless Conductor Bars are the perfect solution for your industrial needs, offering flexibility, durability, and high performance.
Contact us today to learn more about how we can customize our products to fit your specific application.


 

Application:
Electric Hoist Seamless Conductor Bar with PVC Insulation

Application Range

The Seamless Safety Busbar is widely used in industrial power transmission systems, particularly in applications requiring curved and height-adjustable power supply designs. It is an excellent choice for:

  • Crane Power Supply Systems: Ensuring high-speed stability and efficient power delivery.
  • Automated Production Lines: Providing reliable and flexible power transmission solutions.
  • General Industrial Use: Suitable for various industrial environments requiring high-quality electrical components.

 

Product Parameters
Installation Location indoor
ambient temperature -25ºC~+55ºC
Protection level IP20
Protection against electric shock level Level 0
Maximum working voltage AC 660V or DC 1000V
Running speed V≤2000m/min
pollution level Level IIII (general conductive dust and condensation state)
Relative humidity <95%
Maintenance

Selection of Product Specifications: When selecting product specifications, consider the equipment load, duty cycle, ambient temperature, and cable length. Ensure to allow for a margin of safety, and typically reduce the capacity by 20% for outdoor applications.

Collector Wires: Due to the multiple leads in collectors, ensure there is no phase-to-phase short circuit or incorrect assembly.

Annual Maintenance: During the annual maintenance of the equipment, perform the following tasks:

  1. Collector Inspection:

    • Remove the collector from the conduit end.
    • Check for brush wear; if it exceeds the effective length marking, replace the brushes promptly.
    • Inspect the wear on the neck area.
  2. Conduit and Rail Inspection:

    • Check the conduit rail joints for looseness or rust; replace if necessary.
    • Inspect the fixed clamps and suspension clamps for any looseness.
  3. Conduit Condition:

    • Inspect for any significant deformation or bending.
    • Use suspension bolt adjustments to straighten if possible; if not, replace the individual conduits.
  4. Conduit Cleaning:

    • Generally, dust accumulation inside the conduit does not require attention.
    • If there is excessive dust accumulation over time, blow it out with compressed air or wipe it clean with a lint-free cloth.
  5. Brush Spring Pressure:

    • Ensure the spring pressure of the collector brushes is normal, typically between 1.8-2.3 N/cm².
  6. Roller Inspection:

    • Check the wear condition of the rollers.
    • The rollers ensure the brush maintains proper positioning within the conduit.
    • Excessive roller wear can cause brush abrasion or result in intermittent power loss.

Electric Hoist Seamless Conductor Bar with PVC InsulationElectric Hoist Seamless Conductor Bar with PVC InsulationElectric Hoist Seamless Conductor Bar with PVC Insulation

FAQ

Q1: Are you a manufacturer or a trading company?
A: We are a professional trading company that collaborates with original manufacturers for product outsourcing.

Q2: Do you have stock?
A: Yes, we have stock for most standard products.

Q3: What is your minimum order quantity (MOQ)?
A: Generally, our MOQ for standard coaxial cable products is 15-20 meters, but each inquiry is considered individually.

Q4: How do you control quality?
A: We have a very strict quality control system to ensure that our products always have the best quality.

Q5: What is your delivery time?
A: Usually, our delivery time is 15-25 days after the purchase order (PO) is confirmed, but it depends on the quantity for each inquiry.

Q6: What are your usual payment terms?
A: Typically, we require a prepayment and the balance to be paid before shipment, but we quote based on the customer, order, and other factors for each inquiry.

Q7: What are your delivery methods?
A: We usually use FOB, CIF, CFR, etc.

Q8: What is your main packaging mode?
A: Inner packaging: wooden reels, plastic reels, paper reels, shrink wrap; outer packaging: cartons, wooden cases, and pallets. Other packaging methods can be used upon customer confirmation.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now